Page view 35
32
No. 1
DIP-SW1
2 3 4 5 6 7 8
No. 1
DIP-SW2
2 3 4
B-1. Parallel Interface Model
ON ON
OFF OFF
DIP-SW 1
Switch
Function ON OFF
1-1 Command emulation
See table below
1-2 Command emulation
1-3
Should not be changed (Should be set to on)
1-4 Sensor adjustment Valid Invalid
1-5 Pin #31 (INIT) reset signal Valid Invalid
1-6 Handshaking conditions Offline or receive Receive buffer full
(conditions for BUSY) buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)
The factory settings of DIP switch are all on.
Switch 1-1 Switch 1-2 Command emulation
ON ON Star Line Mode
OFF ON Star Page Mode
OFF OFF ESC/POS Mode
DIP-SW 2
Switch
Function ON OFF
2-1
2-2
Always ON Should be set to on
2-3
2-4
The factory settings of DIP switch are all on.